100 kVA Single-Phase Transformer: Complete Specifications & Dimensions

Comprehensive technical data for 100 kVA dry transformers including dimensions, weight, full load amps, installation tips, and sizing guidance

Quick Specifications

Rated Power:100 kVAPhase:Single-Phase
Primary Voltage:480VSecondary Voltage:120/240V
Weight:650 lbs (295 kg)Efficiency:98.9%
Dimensions (H×W×D):50″ × 28″ × 22″ (1270 × 711 × 559 mm)

A 100 kVA transformer is commonly used in Heavy industrial, utility substations. This guide provides complete specifications to help engineers and purchasers select and install 100 kVA transformers correctly.

⚠️ Important: Specifications shown are typical values for reference. Actual dimensions and weights vary by manufacturer. Always verify with manufacturer datasheet before ordering.

100 kVA Transformer Dimensions

100-0-kva-single-phase-transformer-dimensions
100 kVA Single-Phase Transformer Dimensions (Typical)
DimensionMetric (mm)Imperial (inches)
Height (H)1270 mm50″
Width (W)711 mm28″
Depth (D)559 mm22″
🔧 Installation Note: This 100 kVA transformer weighs 650 lbs and requires forklift or crane for installation. Pre-plan access routes and verify floor load capacity (minimum 975 lbs recommended). Allow 24-48 hours for concrete curing if new pad is poured.

100 kVA Transformer Weight

Weight TypePounds (lbs)Kilograms (kg)
Dry-Type Transformer650 lbs295 kg
Oil-Filled Equivalent*~975 lbs~442 kg
Shipping Weight (Approx.)~715 lbs~324 kg

*Oil-filled transformer weight is estimated at approximately 1.5× dry-type weight.


Full Load Amps at Various Voltages

The following table shows calculated full load amperage for a 100 kVA single-phase transformer:

VoltageFull Load AmpsSuggested Wire Size
120V833.3 A750 MCM+
208V480.8 A750 MCM+
240V416.7 A750 MCM+
277V361.0 A500 MCM
480V208.3 A250 MCM
600V166.7 A3/0 AWG
Formula Used:
Single-Phase: Amps = (kVA × 1000) ÷ Voltage
Example at 480V: 208.3 A = (100 × 1000) ÷ 480

Electrical Specifications

ParameterValueNotes
Rated kVA100 kVAAt rated voltage and frequency
Frequency60 Hz50 Hz available on request
No-Load Loss180 WCore/iron losses (typical)
Load Loss750 WCopper losses at 100% load
Total Losses930 WAt 100% load
Impedance4.5%±7.5% tolerance per IEEE
Efficiency98.9%At 100% load
Sound Level~42 dBPer NEMA ST-20 (estimated)

⚠️ Important Considerations for 100 kVA Transformers:

  • Large transformers like this 100 kVA unit generate significant heat. Verify room ventilation capacity before installation.
  • Floor loading of 650 lbs requires structural verification. Contact a structural engineer for slab-on-grade installations.
  • Impedance matching is critical when paralleling transformers. Consult a power systems engineer.

When is a 100 kVA Transformer the Right Choice?

A 100 kVA single-phase transformer is designed for substantial loads:

  • Large commercial facilities (10,000+ sq ft)
  • Industrial workshops with heavy machinery
  • Data center backup power systems
  • Large agricultural operations
  • Mining and extraction equipment

Engineering Considerations:

  • Voltage drop calculations become critical at this size
  • Short circuit current analysis required
  • Consider redundant transformer configuration for critical loads
  • Coordinate overcurrent protection with utility requirements

Typical Load Examples for 100 kVA

Example load distribution for a 100 kVA installation:

Load TypeEstimated Demand
Industrial HVAC25 kVA
Production equipment35 kVA
Facility lighting15 kVA
Compressed air system15 kVA
Office/admin loads10 kVA

Note: Actual loads vary. Always perform a detailed load calculation for your specific application.


Related Transformer Sizes

Compare with adjacent kVA ratings:

kVA RatingLink
75 kVA Single-Phase75 kVA Specifications →
100 kVA Single-PhaseCurrent Page
167 kVA Single-Phase167 kVA Specifications →

Frequently Asked Questions

What are the dimensions of a 100 kVA transformer?

A typical 100 kVA dry single-phase transformer measures approximately 50″ H × 28″ W × 22″ D (1270 × 711 × 559 mm). Dimensions vary by manufacturer.

How much does a 100 kVA transformer weigh?

A 100 kVA dry transformer typically weighs around 650 lbs (295 kg). Oil-filled transformers of the same rating weigh approximately 975 lbs.

What is the full load amperage of a 100 kVA transformer at 480V?

At 480V, a 100 kVA single-phase transformer has a full load current of 208.3 amps.

What loads can a 100 kVA transformer handle?

A 100 kVA transformer can supply up to 100 kVA of apparent power. For typical loads with 0.85 power factor, this equals approximately 85.0 kW of real power.


Related Resources

📊 Complete Reference Charts:

Related Articles


Standards & References

  • IEEE C57.12.01 – General Requirements for Dry-Type Transformers
  • IEEE C57.12.91 – Test Code for Dry-Type Transformers
  • NEMA TP-1 – Guide for Determining Energy Efficiency
  • DOE 10 CFR 431 – Energy Conservation Standards

Disclaimer: Specifications shown are typical reference values compiled from multiple industry sources. Actual specifications vary significantly by manufacturer, model, enclosure type, and configuration. Always consult manufacturer datasheets for exact specifications before ordering or installation. Data accuracy verified using standard electrical engineering formulas. Last updated: January 2026