300 kVA Three-Phase Transformer: Complete Specifications & Dimensions

Comprehensive technical data for 300 kVA dry transformers including dimensions, weight, full load amps, installation tips, and sizing guidance

Quick Specifications

Rated Power:300 kVAPhase:Three-Phase
Primary Voltage:480VSecondary Voltage:208Y/120V
Weight:1300 lbs (590 kg)Efficiency:99.0%
Dimensions (H×W×D):58″ × 32″ × 28″ (1473 × 813 × 711 mm)

A 300 kVA transformer is commonly used in Major industrial facilities. This guide provides complete specifications to help engineers and purchasers select and install 300 kVA transformers correctly.

⚠️ Important: Specifications shown are typical values for reference. Actual dimensions and weights vary by manufacturer. Always verify with manufacturer datasheet before ordering.

300 kVA Transformer Dimensions

300-0-kva-three-phase-transformer-dimensions
300 kVA Three-Phase Transformer Dimensions (Typical)
DimensionMetric (mm)Imperial (inches)
Height (H)1473 mm58″
Width (W)813 mm32″
Depth (D)711 mm28″
🔧 Installation Note: At 1300 lbs, this 300 kVA transformer is a major installation requiring crane service and specialized rigging. Coordinate with structural engineer for concrete pad design. Plan for extended lead times and specialized transportation requirements.

300 kVA Transformer Weight

Weight TypePounds (lbs)Kilograms (kg)
Dry-Type Transformer1300 lbs590 kg
Oil-Filled Equivalent*~1950 lbs~885 kg
Shipping Weight (Approx.)~1430 lbs~649 kg

*Oil-filled transformer weight is estimated at approximately 1.5× dry-type weight.


Full Load Amps at Various Voltages

The following table shows calculated full load amperage for a 300 kVA three-phase transformer:

VoltageFull Load AmpsSuggested Wire Size
120V1443.4 A750 MCM+
208V832.7 A750 MCM+
240V721.7 A750 MCM+
277V625.3 A750 MCM+
480V360.9 A500 MCM
600V288.7 A400 MCM
Formula Used:
Three-Phase: Amps = (kVA × 1000) ÷ (Voltage × 1.732)
Example at 480V: 360.9 A = (300 × 1000) ÷ (480 × 1.732)

Electrical Specifications

ParameterValueNotes
Rated kVA300 kVAAt rated voltage and frequency
Frequency60 Hz50 Hz available on request
No-Load Loss420 WCore/iron losses (typical)
Load Loss1900 WCopper losses at 100% load
Total Losses2320 WAt 100% load
Impedance5.5%±7.5% tolerance per IEEE
Efficiency99.0%At 100% load
Sound Level~46 dBPer NEMA ST-20 (estimated)
⚠️ Important Considerations for 300 kVA Transformers:

  • Large transformers like this 300 kVA unit generate significant heat. Verify room ventilation capacity before installation.
  • Floor loading of 1300 lbs requires structural verification. Contact a structural engineer for slab-on-grade installations.
  • Impedance matching is critical when paralleling transformers. Consult a power systems engineer.

When is a 300 kVA Three-Phase Transformer the Right Choice?

A 300 kVA three-phase transformer is designed for:

  • Medium industrial facilities and machine shops
  • Multi-story commercial buildings
  • Large HVAC central plant systems
  • Printing and packaging operations
  • Food processing facilities

Capacity Planning:

At 300 kVA, you can support approximately 179 HP of combined motor load at 80% efficiency and 0.85 power factor.

Typical Load Examples for 300 kVA

Example load distribution for a 300 kVA installation:

Load TypeEstimated Demand
Process motors105 kVA
HVAC chillers75 kVA
Lighting systems36 kVA
Welding equipment45 kVA
Support systems39 kVA

Note: Actual loads vary. Always perform a detailed load calculation for your specific application.


Related Transformer Sizes

Compare with adjacent kVA ratings:

kVA RatingLink
225 kVA Three-Phase225 kVA Specifications →
300 kVA Three-PhaseCurrent Page
500 kVA Three-Phase500 kVA Specifications →

Frequently Asked Questions

What are the dimensions of a 300 kVA transformer?

A typical 300 kVA dry three-phase transformer measures approximately 58″ H × 32″ W × 28″ D (1473 × 813 × 711 mm). Dimensions vary by manufacturer.

How much does a 300 kVA transformer weigh?

A 300 kVA dry transformer typically weighs around 1300 lbs (590 kg). Oil-filled transformers of the same rating weigh approximately 1950 lbs.

What is the full load amperage of a 300 kVA transformer at 480V?

At 480V, a 300 kVA three-phase transformer has a full load current of 360.9 amps.

What loads can a 300 kVA transformer handle?

A 300 kVA transformer can supply up to 300 kVA of apparent power. For typical loads with 0.85 power factor, this equals approximately 255.0 kW of real power.


Related Resources

📊 Complete Reference Charts:

Related Articles


Standards & References

  • IEEE C57.12.01 – General Requirements for Dry-Type Transformers
  • IEEE C57.12.91 – Test Code for Dry-Type Transformers
  • NEMA TP-1 – Guide for Determining Energy Efficiency
  • DOE 10 CFR 431 – Energy Conservation Standards

Disclaimer: Specifications shown are typical reference values compiled from multiple industry sources. Actual specifications vary significantly by manufacturer, model, enclosure type, and configuration. Always consult manufacturer datasheets for exact specifications before ordering or installation. Data accuracy verified using standard electrical engineering formulas. Last updated: January 2026

Scroll to Top