15 kVA Single-Phase Transformer: Complete Specifications & Dimensions

Comprehensive technical data for 15 kVA dry transformers including dimensions, weight, full load amps, installation tips, and sizing guidance

Quick Specifications

Rated Power:15 kVAPhase:Single-Phase
Primary Voltage:480VSecondary Voltage:120/240V
Weight:170 lbs (77 kg)Efficiency:98.2%
Dimensions (H×W×D):30″ × 17″ × 13″ (762 × 432 × 330 mm)

A 15 kVA transformer is commonly used in Medium commercial loads, retail stores. This guide provides complete specifications to help engineers and purchasers select and install 15 kVA transformers correctly.

⚠️ Important: Specifications shown are typical values for reference. Actual dimensions and weights vary by manufacturer. Always verify with manufacturer datasheet before ordering.

15 kVA Transformer Dimensions

15-0-kva-single-phase-transformer-dimensions
15 kVA Single-Phase Transformer Dimensions (Typical)
DimensionMetric (mm)Imperial (inches)
Height (H)762 mm30″
Width (W)432 mm17″
Depth (D)330 mm13″
🔧 Installation Note: At 170 lbs, this 15 kVA transformer requires proper rigging equipment for installation. Use a pallet jack or forklift for safe positioning. Ensure floor can support the load plus any additional connected equipment weight.

15 kVA Transformer Weight

Weight TypePounds (lbs)Kilograms (kg)
Dry-Type Transformer170 lbs77 kg
Oil-Filled Equivalent*~255 lbs~115 kg
Shipping Weight (Approx.)~187 lbs~84 kg

*Oil-filled transformer weight is estimated at approximately 1.5× dry-type weight.


Full Load Amps at Various Voltages

The following table shows calculated full load amperage for a 15 kVA single-phase transformer:

VoltageFull Load AmpsSuggested Wire Size
120V125.0 A1/0 AWG
208V72.1 A#3 AWG
240V62.5 A#4 AWG
277V54.2 A#6 AWG
480V31.2 A#8 AWG
600V25.0 A#10 AWG
Formula Used:
Single-Phase: Amps = (kVA × 1000) ÷ Voltage
Example at 480V: 31.2 A = (15 × 1000) ÷ 480

Electrical Specifications

ParameterValueNotes
Rated kVA15 kVAAt rated voltage and frequency
Frequency60 Hz50 Hz available on request
No-Load Loss60 WCore/iron losses (typical)
Load Loss180 WCopper losses at 100% load
Total Losses240 WAt 100% load
Impedance3.5%±7.5% tolerance per IEEE
Efficiency98.2%At 100% load
Sound Level~40 dBPer NEMA ST-20 (estimated)

⚠️ Important Considerations for 15 kVA Transformers:

  • At 15 kVA, ensure adequate ventilation clearance (minimum 3″ sides, 6″ top) for proper cooling.

When is a 15 kVA Transformer the Right Choice?

A 15 kVA single-phase transformer is well-suited for:

  • Medium commercial buildings (3,000-8,000 sq ft)
  • Light manufacturing with motors up to 9 HP total
  • Retail stores with significant lighting and HVAC loads
  • Dedicated equipment power for CNC machines or welders
  • Agricultural operations with irrigation pumps

Load Calculation Example:

A typical 15 kVA installation might include: Lighting (8 kW) + HVAC (4 kVA) + Equipment (6 kVA) = 12 kVA total demand with diversity factor.

Typical Load Examples for 15 kVA

Example load distribution for a 15 kVA installation:

Load TypeEstimated Demand
Commercial HVAC system5 kVA
Retail store lighting3 kVA
Point-of-sale equipment0 kVA
Refrigeration units3 kVA
Miscellaneous loads2 kVA

Note: Actual loads vary. Always perform a detailed load calculation for your specific application.


Related Transformer Sizes

Compare with adjacent kVA ratings:

kVA RatingLink
10 kVA Single-Phase10 kVA Specifications →
15 kVA Single-PhaseCurrent Page
25 kVA Single-Phase25 kVA Specifications →

Frequently Asked Questions

What are the dimensions of a 15 kVA transformer?

A typical 15 kVA dry single-phase transformer measures approximately 30″ H × 17″ W × 13″ D (762 × 432 × 330 mm). Dimensions vary by manufacturer.

How much does a 15 kVA transformer weigh?

A 15 kVA dry transformer typically weighs around 170 lbs (77 kg). Oil-filled transformers of the same rating weigh approximately 255 lbs.

What is the full load amperage of a 15 kVA transformer at 480V?

At 480V, a 15 kVA single-phase transformer has a full load current of 31.2 amps.

What loads can a 15 kVA transformer handle?

A 15 kVA transformer can supply up to 15 kVA of apparent power. For typical loads with 0.85 power factor, this equals approximately 12.8 kW of real power.


Related Resources

📊 Complete Reference Charts:

Related Articles


Standards & References

  • IEEE C57.12.01 – General Requirements for Dry-Type Transformers
  • IEEE C57.12.91 – Test Code for Dry-Type Transformers
  • NEMA TP-1 – Guide for Determining Energy Efficiency
  • DOE 10 CFR 431 – Energy Conservation Standards

Disclaimer: Specifications shown are typical reference values compiled from multiple industry sources. Actual specifications vary significantly by manufacturer, model, enclosure type, and configuration. Always consult manufacturer datasheets for exact specifications before ordering or installation. Data accuracy verified using standard electrical engineering formulas. Last updated: January 2026