45 kVA Three-Phase Transformer: Complete Specifications & Dimensions

Comprehensive technical data for 45 kVA dry transformers including dimensions, weight, full load amps, installation tips, and sizing guidance

Quick Specifications

Rated Power:45 kVAPhase:Three-Phase
Primary Voltage:480VSecondary Voltage:208Y/120V
Weight:360 lbs (163 kg)Efficiency:98.5%
Dimensions (H×W×D):38″ × 22″ × 17″ (965 × 559 × 432 mm)

A 45 kVA transformer is commonly used in Medium commercial facilities. This guide provides complete specifications to help engineers and purchasers select and install 45 kVA transformers correctly.

⚠️ Important: Specifications shown are typical values for reference. Actual dimensions and weights vary by manufacturer. Always verify with manufacturer datasheet before ordering.

45 kVA Transformer Dimensions

45-0-kva-three-phase-transformer-dimensions
45-0-kva-three-phase-transformer-dimensions
45 kVA Three-Phase Transformer Dimensions (Typical)
DimensionMetric (mm)Imperial (inches)
Height (H)965 mm38″
Width (W)559 mm22″
Depth (D)432 mm17″
🔧 Installation Note: This 45 kVA transformer weighs 360 lbs and requires forklift or crane for installation. Pre-plan access routes and verify floor load capacity (minimum 540 lbs recommended). Allow 24-48 hours for concrete curing if new pad is poured.

45 kVA Transformer Weight

Weight TypePounds (lbs)Kilograms (kg)
Dry-Type Transformer360 lbs163 kg
Oil-Filled Equivalent*~540 lbs~244 kg
Shipping Weight (Approx.)~396 lbs~179 kg

*Oil-filled transformer weight is estimated at approximately 1.5× dry-type weight.


Full Load Amps at Various Voltages

The following table shows calculated full load amperage for a 45 kVA three-phase transformer:

VoltageFull Load AmpsSuggested Wire Size
120V216.5 A250 MCM
208V124.9 A1/0 AWG
240V108.3 A#1 AWG
277V93.8 A#2 AWG
480V54.1 A#6 AWG
600V43.3 A#6 AWG
Formula Used:
Three-Phase: Amps = (kVA × 1000) ÷ (Voltage × 1.732)
Example at 480V: 54.1 A = (45 × 1000) ÷ (480 × 1.732)

Electrical Specifications

ParameterValueNotes
Rated kVA45 kVAAt rated voltage and frequency
Frequency60 Hz50 Hz available on request
No-Load Loss130 WCore/iron losses (typical)
Load Loss480 WCopper losses at 100% load
Total Losses610 WAt 100% load
Impedance4.0%±7.5% tolerance per IEEE
Efficiency98.5%At 100% load
Sound Level~40 dBPer NEMA ST-20 (estimated)

⚠️ Important Considerations for 45 kVA Transformers:

  • At 45 kVA, ensure adequate ventilation clearance (minimum 3″ sides, 6″ top) for proper cooling.

When is a 45 kVA Three-Phase Transformer the Right Choice?

A 45 kVA three-phase transformer is ideal for:

  • Small manufacturing facilities with 3-phase equipment
  • Commercial kitchens with three-phase ovens
  • HVAC systems with 3-phase compressors up to 22 HP
  • Elevator and escalator power supply
  • Multi-tenant building common areas

Three-Phase Advantage: Compared to single-phase, this transformer delivers 39.0 kW at unity power factor with balanced loading across all phases.

Typical Load Examples for 45 kVA

Example load distribution for a 45 kVA installation:

Load TypeEstimated Demand
Three-phase HVAC compressor18 kVA
3-phase motors (combined)13 kVA
Lighting transformer6 kVA
Receptacle loads6 kVA

Note: Actual loads vary. Always perform a detailed load calculation for your specific application.


Related Transformer Sizes

Compare with adjacent kVA ratings:

kVA RatingLink
30 kVA Three-Phase30 kVA Specifications →
45 kVA Three-PhaseCurrent Page
75 kVA Three-Phase75 kVA Specifications →

Frequently Asked Questions

What are the dimensions of a 45 kVA transformer?

A typical 45 kVA dry three-phase transformer measures approximately 38″ H × 22″ W × 17″ D (965 × 559 × 432 mm). Dimensions vary by manufacturer.

How much does a 45 kVA transformer weigh?

A 45 kVA dry transformer typically weighs around 360 lbs (163 kg). Oil-filled transformers of the same rating weigh approximately 540 lbs.

What is the full load amperage of a 45 kVA transformer at 480V?

At 480V, a 45 kVA three-phase transformer has a full load current of 54.1 amps.

What loads can a 45 kVA transformer handle?

A 45 kVA transformer can supply up to 45 kVA of apparent power. For typical loads with 0.85 power factor, this equals approximately 38.2 kW of real power.


Related Resources

📊 Complete Reference Charts:

Related Articles


Standards & References

  • IEEE C57.12.01 – General Requirements for Dry-Type Transformers
  • IEEE C57.12.91 – Test Code for Dry-Type Transformers
  • NEMA TP-1 – Guide for Determining Energy Efficiency
  • DOE 10 CFR 431 – Energy Conservation Standards

Disclaimer: Specifications shown are typical reference values compiled from multiple industry sources. Actual specifications vary significantly by manufacturer, model, enclosure type, and configuration. Always consult manufacturer datasheets for exact specifications before ordering or installation. Data accuracy verified using standard electrical engineering formulas. Last updated: January 2026

Scroll to Top