100.0 kVA Single-Phase Padmount Transformer: Complete Specifications

Comprehensive specifications for 100.0 kVA dead-front padmount transformer including dimensions, weight, concrete pad requirements, and electrical data

Quick Specifications

Rated Power:100.0 kVAPhase:Single-Phase
Primary Voltage:12470GY/7200Secondary Voltage:120/240
Enclosure:Dead-FrontCooling:ONAN
Weight:1300 lbs (590 kg)Concrete Pad:60″ × 60″
Dimensions (H×W×D):32″ × 40″ × 41″ (813 × 1016 × 1029 mm)

A 100.0 kVA padmount transformer is a ground-mounted, oil-filled distribution transformer commonly used in large commercial, small industrial. This guide provides complete specifications for utility engineers, electrical contractors, and facility planners.

✅ Dead-Front Design: All primary and secondary connections are made inside the locked cabinet, eliminating exposed live parts. This design meets ANSI/IEEE C57.12.28 safety standards for public areas.

100.0 kVA Padmount Transformer Dimensions

100-0-kva-single-phase-padmount-transformer-dimensions
100.0 kVA Single-Phase Padmount Transformer Dimensions (Typical)
DimensionMetric (mm)Imperial (inches)
Height (H)813 mm32″
Width (W)1016 mm40″
Depth (D)1029 mm41″
🔧 Installation Note: Unit weight of 1300 lbs allows forklift installation. Concrete pad must be level within 1/4 inch per foot and fully cured (28 days minimum). Maintain minimum 10 feet clearance from buildings per NEC and local fire codes.

Concrete Pad Requirements

The 100.0 kVA padmount transformer requires a properly designed concrete pad for installation:

Pad SpecificationRequirementNotes
Minimum Pad Size60″ × 60″Allow 6″ overhang on all sides
Pad Thickness4-6 inchesReinforced concrete, 3000 PSI minimum
Grade/SlopeLevel ± 1/4″/ftSlight slope away from buildings
Conduit EntryPer utility specsPrimary and secondary duct banks
Curing Time28 days minimumBefore transformer placement

Weight and Oil Specifications

SpecificationValueNotes
Total Weight (with oil)1300 lbs (590 kg)Includes all oil and accessories
Oil Volume70 gallons (265 L)Mineral insulating oil
Cooling ClassONANOil Natural, Air Natural
BIL Rating95 kVBasic Insulation Level

Electrical Specifications

ParameterValueNotes
Rated kVA100.0 kVAAt rated voltage and ONAN cooling
Primary Voltage12470GY/7200With taps ±2.5%, ±5%
Secondary Voltage120/240Standard service voltage
No-Load Loss175 WCore losses
Load Loss820 WAt rated load
Total Losses995 WAt 100% load
Impedance2.5%Per IEEE C57.12.00
Efficiency99.0%DOE 2016 compliant

Secondary Full Load Amps

Full load amperage at secondary voltage for 100.0 kVA single-phase padmount transformer:

Secondary VoltageFull Load AmpsConductor Size
120V833.3 A750+ MCM
208V480.8 A750+ MCM
240V416.7 A750+ MCM
277V361.0 A500 MCM
480V208.3 A4/0 AWG
Formula:
Single-Phase: Amps = (kVA × 1000) ÷ Voltage
Example at 240V: 416.7 A = (100.0 × 1000) ÷ 240

When to Choose a 100.0 kVA Padmount Transformer

A 100.0 kVA single-phase padmount transformer is commonly specified for medium commercial facilities, multi-family housing complexes, and retail centers.

Typical Load Distribution for 100.0 kVA Padmount Transformer

Load TypeEstimated Demand
Residential cluster (8-15 homes)60 kVA
Small commercial25 kVA
Outdoor lighting10 kVA

Note: Load estimates are typical values. Consult project load study for specific applications.


Related Padmount Transformer Sizes

Compare with adjacent kVA ratings:

kVA RatingLink
75.0 kVA Single-Phase75.0 kVA Padmount Specs →
100.0 kVA Single-PhaseCurrent Page
167.0 kVA Single-Phase167.0 kVA Padmount Specs →

Frequently Asked Questions

What size concrete pad do I need for a 100.0 kVA padmount transformer?

A 100.0 kVA padmount transformer requires a minimum pad size of 60″ × 60″ with 4-6 inches thickness of reinforced concrete.

How much does a 100.0 kVA padmount transformer weigh?

A 100.0 kVA padmount transformer weighs approximately 1300 lbs (590 kg) including oil.

What is the difference between dead-front and live-front padmount transformers?

Dead-front designs (like this 100.0 kVA unit) have all connections inside the locked cabinet with no exposed live parts. Live-front designs have bushings exposed on top, requiring additional safety barriers in public areas.


Related Resources

📊 Padmount Reference Charts:

Related Articles


Standards & References


Disclaimer: Specifications shown are typical reference values compliant with IEEE and DOE standards. Actual specifications vary by manufacturer and specific configuration. Always consult manufacturer datasheets and local utility requirements. Last updated: January 2026